Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
2.
Arq. bras. oftalmol ; 85(4): 359-363, July-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383826

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to investigate the postoperative outcomes and evaluate the success predictors of phacoemulsification with Kahook Dual Blade goniotomy for cataract and glaucoma management in eyes with primary open-angle glaucoma. Methods: This was a retrospective, non-comparative; inter ventional case series in which all patients with primary open-angle glaucoma who underwent phacoemulsification with Kahook Dual Blade goniotomy between June 2018 and April 2019 were enrolled. All the participants had a minimum follow-up period of 6 months. Preoperative and postoperative intraocular pressure values (at 1, 3, and 6 months), number of antiglaucoma medications, best-corrected visual acuity, surgical complications, and any subsequent related events or procedures were recorded. A logistic regression analysis was performed to investigate the association between the different variables and surgical outcomes. Results: A total of 47 patients (57 eyes) were included (mean age, 70.5 ± 7 years). The mean intraocular pressure was reduced from 15.5 ± 4.2 mmHg to 12.2 ± 2.4 mmHg at the last follow-up visit (p<0.001). The mean number of antiglaucoma medications decreased significantly from 1.9 ± 1.0 to 0.6 ± 1.0 during the same period (p<0.001). On the basis of the predefined criterion (intraocular pressure reduction ≥20% and/or reduction ≥1 medication), the 6-month success rate was 86%. A higher preoperative intraocular pressure value (odds ratio [OR]= 2.01; p=0.016) and greater percentage of initial (30 days) intraocular pressure reduction (OR= 1.02; p=0.033) were sig nificantly associated with surgical success. Conclusion: Our findings suggest that phacoemulsification with Kahook Dual Blade goniotomy is an effective and safe alternative for cataract management in eyes with primary open-angle glaucoma that positively impacts intraocular pressure control and medication burden. Eyes with higher baseline intraocular pressure and a more pronounced initial response to the procedure appeared to present better outcomes at 6 months. Further studies are needed to evaluate the long-term efficacy and safety profile of the procedure.


RESUMO Objetivo: Investigar os resultados pós-operatórios e avaliar os preditores de sucesso da facoemulsificação combinada à goniotomia com o Kahook Dual Blade para o tratamento da catarata e do glaucoma em olhos com glaucoma primário de ângulo aberto. Métodos: Série de casos retrospectivos, não comparativos e intervencionistas, em que todos os pacientes com glaucoma primário de ângulo aberto submetidos ao procedimento de facoemulsificação combinada à goniotomia com o Kahook Dual Blade entre junho de 2018 e abril de 2019 foram inscritos. Todos os participantes tiveram um acompanhamento mínimo de 6 meses. Foram registrados os valores de pressão intraocular pré e pós-operatória (em 1, 3 e 6 meses), número de medicamentos antiglaucomatosos, melhor acuidade visual corrigida, complicações cirúrgicas e quaisquer eventos ou procedimentos subsequentes relacionados. A análise de regressão logística foi usada para investigar a associação entre diferentes variáveis e resultados cirúrgicos. Resultados: Um total de 57 olhos de 47 pacientes foram incluídos (média de idade, 70,5 ± 7 anos). A pressão intraocular média reduziu de 15,5 ± 4,2 mmHg para 12,2 ± 2,4 mmHg na última visita de acompanhamento (p<0,001). O número médio de medicamentos antiglaucomatosos diminuiu significativamente de 1,9 ± 1,0 para 0,6 ± 1,0 durante o mesmo período (p<0,001). Com base no critério predefinido (redução da pressão intraocular ≥20% e/ou redução de ≥1 medicamento), a taxa de sucesso em 6 meses foi de 86%. Um valor de pressão intraocular pré-operatório mais alto (OR= 2,01; p=0,016) e maior porcentagem de redução da pressão intraocular inicial (30 dias) (OR= 1,02; p=0,033) foram significativamente associados ao sucesso cirúrgico. Conclusão: Nossos resultados sugerem que o procedimento de facoemulsificação combinada à goniotomia com o Kahook Dual Blade é uma alternativa eficaz e segura para o manejo da catarata em olhos com glaucoma primário de ângulo aberto, impactando positivamente no controle da pressão intraocular e no número de medicamentos. Olhos com pressão intraocular basal mais alta e resposta inicial mais pronunciada ao procedimento parecem apresentar melhores resultados em 6 meses. Mais estudos são necessários para avaliar a eficácia em longo prazo e o perfil de segurança.

3.
Arq. bras. oftalmol ; 85(4): 344-350, July-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383831

ABSTRACT

ABSTRACT Purpose: To investigate the reduction in corneal endothelial cell density associated with gonioscopy-assisted transluminal trabeculotomy (GATT) in a short-term follow-up period. Methods: A retrospective analysis of the medical charts of patients with open-angle glaucoma who underwent gonioscopy-assisted transluminal trabeculotomy isolated or combined with phacoemulsification (phaco-gonioscopy-assisted transluminal trabeculotomy) was conducted. Patients who underwent phacoemulsification alone were included as controls. The endothelial cell density data (assessed using a specular microscope) before and at the first month after operation were collected and then compared. Results: Sixty-two eyes previously treated with gonioscopy-assisted transluminal trabeculotomy (gonioscopy-assisted transluminal trabeculotomy, n=39 eyes; phaco-gonioscopy-assisted transluminal trabeculotomy, n=23 eyes) fulfilled the inclusion criteria. The mean age of the study patients was 61.3 ± 18.4 years in the stand-alone gonioscopyassisted transluminal trabeculotomy group and 60.4 ± 11.9 in phaco-gonioscopy-assisted transluminal trabeculotomy group. Men comprised 66.6% of the patients in the isolated gonioscopyassisted transluminal trabeculotomy group and 56.5% of those in the phaco-gonioscopy-assisted transluminal trabeculotomy group. The mean visual field defects (mean deviation index) were -13.9 ± 9.2 and -10.3 ± 7.7 dB in the isolated gonioscopy-assisted and phaco-gonioscopy-assisted transluminal trabeculotomy groups, respectively. The patients in the former group presented a mean endothelial cell density reduction of 28.8 cells/mm² (1.31%; p=0.467). In the latter group, the mean endothelial cell density loss was 89.4 cells/mm² (4.36%; p=0.028). The control eyes (23 patients) presented a mean endothelial cell density change of 114.1 ± 159.8 cells/mm² (4.41%; p=0.505). The endothelial cell density reduction in the phaco-gonioscopy-assisted transluminal trabeculotomy group was not significantly different from that in the controls (p=0.81). Conclusions: Gonioscopy-assisted transluminal trabeculotomy appears to be a safe procedure for the corneal endothelial cell layer when performed either isolated or combined with cataract extraction in a short-term follow-up period.


RESUMO Objetivo: Investigar a redução na densidade celular endotelial corneana associada à trabeculotomia transluminal assistida por gonioscopia (GATT) em curto prazo. Métodos: Análise retrospectiva de prontuários médicos de pacientes com glaucoma de ângulo aberto que foram submetidos à trabeculotomia transluminal assistida por gonioscopia isolada ou combinada com facoemulsificação. Pacientes que foram submetidos à facoemulsificação isolada foram incluídos como controles. Dados da densidade celular endotelial corneana (avaliada através de microscópio especular) pré-operatória e ao primeiro mês pós-operatório foram coletados e comparados. Resultados: Sessenta e dois olhos que foram submetidos à trabeculotomia transluminal assistida por gonioscopia (trabeculotomia transluminal assistida por gonioscopia=39 olhos; faco com trabeculotomia transluminal assistida por gonioscopia=23 olhos) passaram pelos critérios de inclusão. A idade média dos pacientes estudados era 61,3 ± 18,4 anos no grupo trabeculotomia transluminal assistida por gonioscopia isolada e 60,4 ± 11,9 anos no grupo faco com trabeculotomia transluminal assistida por gonioscopia. Homens eram 66,6% do grupo trabeculotomia transluminal assistida por gonioscopia isolada e 56,5% do grupo faco com trabeculotomia transluminal assistida por gonioscopia. O defeito perimétrico médio (Mean Deviation) era -13,9 ± 9,2 dB e -10,3 ± 7,7 dB nos grupos trabeculotomia transluminal assistida por gonioscopia isolada e faco com trabeculotomia transluminal assistida por gonioscopia respectivamente. O grupo que fora submetido à trabeculotomia transluminal assistida por gonioscopia isolada apresentou redução média da densidade celular endotelial corneana de 28,8 células/mm² (1,31%; p=0,467). No grupo faco com trabeculotomia transluminal assistida por gonioscopia, a redução média da densidade celular endotelial corneana foi de 89,4 células/mm² (4,36%; p=0,028). Olhos controle (23 olhos) apresentaram redução média da densidade celular endotelial corneana de 114,1 ± 159,8 células/mm² (4,41%; p=0,505). A redução na densidade celular endotelial corneana no grupo faco com trabeculotomia transluminal assistida por gonioscopia não foi significativamente diferente do grupo controle (p=0,81). Conclusões: A trabeculotomia transluminal assistida por gonioscopia parece ser segura para a camada endotelial corneana em um curto prazo quando realizada de forma isolada ou combinada com cirurgia de catarata.

4.
Arq. bras. oftalmol ; 84(4): 380-382, July-Aug. 2021. graf
Article in English | LILACS | ID: biblio-1285296

ABSTRACT

ABSTRACT The aim of this study is to present the results of ab-interno trabeculotomy using Kahook Dual Blade in patients with primary congenital glaucoma. An ab-interno trabeculotomy using a dual blade device was performed in three eyes of two patients with the diagnosis of primary congenital glaucoma. One of them in the left eye and the other patient in both eyes. In the first patient, an adequate response was achieved after the intraocular pressure reduced from 36 mmHg to 14 mmHg. The second patient did not respond adequately to the procedure, and high intraocular pressure levels persisted in both eyes after the procedure. The indication of Kahook Dual Blade ab-interno trabeculotomy in primary congenital glaucoma must be cautious and more studies are needed to establish its efficacy and the best indications. Seems that this procedure should not be indicated for primary congenital glaucoma treatment.


RESUMO O objetivo deste estudo é apresentar os resultados da trabeculotomia ab-interno com Kahook Dual Blade em pacientes com glaucoma congênito primário. Foi realizada trabeculotomia ab-interno com dispositivo de lâmina dupla em 3 olhos de 2 pacientes com diagnóstico de glaucoma congênito primário. Um deles no olho esquerdo e o outro paciente nos dois olhos. No primeiro paciente, houve resposta adequada uma vez que a pressão intraocular diminuiu de 36 mmHg para 14mmHg. O segundo paciente não respondeu adequadamente ao procedimento, mantendo altos níveis de pressão intraocular em ambos os olhos após o procedimento. A indicação da trabeculotomia ab-interno com o Kahook Dual Blade no glaucoma congênito primário deve ser cautelosa e são necessários mais estudos para estabelecer a eficácia e as melhores indicações. Parece que esse procedimento não deve ser indicado no tratamento do glaucoma congênito primário.


Subject(s)
Humans , Trabeculectomy , Optic Nerve Diseases , Glaucoma , Tonometry, Ocular , Glaucoma/surgery , Retrospective Studies , Treatment Outcome , Intraocular Pressure
5.
Arq. bras. oftalmol ; 82(3): 176-182, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001308

ABSTRACT

ABSTRACT Purpose: To correlate provocative test-based intraocular pressure (IOP) variation parameters (fluctuation and peak) with functional status, and to compare these IOP parameters between treated eyes with asymmetric primary open-angle glaucoma (POAG). Methods: A prospective observational study including consecutively treated patients with primary open-angle glaucoma was performed. Subjects with ocular diseases other than glaucoma or previous incisional glaucoma surgery were excluded. The primary inclusion criteria were 33 visual field tests and 32 years of follow-up, without any changes on current medical regimen. Long-term intraocular pressure parameters were acquired via isolated intraocular pressure measurements from the patients' last 5 office visits. To evaluate provocative test-based intraocular pressure parameters, all patients were submitted to a water drinking test. Initially, the partial correlation coefficients between each intraocular pressure variation parameter and visual field mean deviation were calculated, adjusting for the baseline intraocular pressure and number of antiglaucoma medications. In addition, each intraocular pressure parameter was compared between eyes with better visual field mean deviation and fellow eyes with worse visual field mean deviation in patients with asymmetric visual field loss (defined as an inter-eye visual field mean deviation difference of at least 3 dB). Results: A total of 87 eyes (87 patients; mean age, 61.9 ± 12.5 years; 59.8% women) with primary open-angle glaucoma were included. The patients underwent a median of 5 visual field tests, with a mean follow-up of 4.3 ± 1.4 years. Neither long-term nor water-drinking test intraocular pressure variation parameters were significantly associated with visual field mean deviation values (p30.117). In the subgroup with asymmetric visual field loss (64 eyes of 32 patients; mean age, 65.0 ± 11.4 years), neither long-term water-drinking test intraocular pressure variation parameters differed significantly between eyes with better and worse visual field mean deviation (p30.400). Conclusion: Our results indicate that neither long-term intraocular pressure variation parameters nor stress test-derived intraocular pressure metrics, as assessed by the water-drinking test, appear to correlate with the visual field status or differ significantly between eyes with asymmetric visual field damage, suggesting that other factors may explain such functional asymmetry, and that the water-drinking test does not add significant information to these cases.


RESUMO Objetivo: Correlacionar os parâmetros de variação da pressão intraocular (flutuação e pico) com o dano funcional em pacientes tratados com glaucoma primário de ângulo aberto, e comparar esses parâmetros de pressão intraocular entre olhos com dano funcional assimétrico. Métodos: Estudo observacio nal prospectivo foi realizado incluindo consecutivamente pa cientes tratados com glaucoma primário de ângulo aberto. Foram excluídos indivíduos com outras doenças oculares que não o glaucoma ou cirurgia prévia incisional de glaucoma. Os principais critérios de inclusão foram: 33 testes de campo visual e 32 anos de acompanhamento, sem quaisquer alterações no regime medicamentoso atual. Parâmetros de pressão intraocular de longo prazo foram obtidos através de medidas de pressão intraocular isoladas de cada consulta (as últimas 5 consultas de cada paciente foram consideradas para análise). Para avaliação dos parâmetros de pressão intraocular de curto prazo, todos os pacientes foram submetidos ao teste de sobrecarga hídrica. Ini cialmente, calculamos os coeficientes de correlação parcial de cada parâmetro de variação da pressão intraocular com o nível de dano funcional, baseado no índice Mean Deviation (MD), ajustando para a pressão intraocular basal e o número de medicações antiglaucomatosas. Além disso, comparamos cada parâmetro de pressão intraocular entre os olhos com melhor e pior nível de dano funcional em pacientes com perda de campo visual assimétrica (definida como diferença no índice mean deviation entre os olhos de pelo menos 3 dB). Resultados: Foram incluídos 87 olhos (87 pacientes) com glaucoma primário de ângulo aberto. A idade média foi de 61,9 ± 12,5 anos e 59,8% eram mulheres. Em geral, os pacientes foram submetidos a 5 testes (mediana) de campo visual, com um seguimento médio de 4,3 ± 1,4 anos. Nem os parâmetros de variação da pressão intraocular de longo prazo nem aqueles obtidos pelo teste de sobrecarga hídrica se correlacionaram significativamente com o nível de dano no campo visual (p30,117). No subgrupo com perda de campo visual assimétrica (64 olhos de 32 pacientes; idade média, 65,0 ± 11,4 anos), nem os parâmetros de variação da pressão intraocular de longo prazo nem os obtidos pelo teste de sobrecarga hídrica diferiram significativamente entre olhos com melhor e pior nível de dano funcional (p3 0,400). Conclusão: Nossos resultados indicam que não apenas parâmetros de variação da pressão intraocular de longo prazo, mas também medidas de pressão intraocular derivadas do teste de sobrecarga hídrica, não parecem se correlacionar com o nível de dano do campo visual, nem diferem significativamente entre olhos com nível de dano funcional assimétrico. Esses achados sugerem que outros fatores poderiam explicar essa assimetria funcional e que o teste de sobrecarga hídrica não acrescenta informações significativas a esses casos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Glaucoma, Open-Angle/physiopathology , Intraocular Pressure/physiology , Reference Values , Time Factors , Tonometry, Ocular , Water/physiology , Visual Fields/physiology , Glaucoma, Open-Angle/therapy , Prospective Studies , Statistics, Nonparametric , Visual Field Tests
6.
Arq. bras. oftalmol ; 79(6): 417-421, Nov.-Dec. 2016. tab
Article in English | LILACS | ID: biblio-838749

ABSTRACT

ABSTRACT Although eye drops are frequently used as an initial treatment option for open angle glaucoma (OAG), side effects, and poor adherence, among others, may compromise treatment efficacy. In this scenario, laser trabeculoplasty is an interesting therapeutic option for open angle glaucoma cases. Commonly used for many years as a last alternative prior to glaucoma incisional surgery, laser trabeculoplasty has been changing its indication after the advent of selective laser trabeculoplasty (SLT). In the current review, we critically evaluated the published data regarding the use of laser trabeculoplasty as a first treatment option for open angle glaucoma patients. Studies using SLT as a first-line treatment have encouraging findings. One-year efficacy results are comparable to those obtained with prostaglandin analogues, with a good safety profile. Although the laser´s effect is known to be transitory, recent data suggest it can be successfully repeated in cases with good response to the first SLT treatment.


RESUMO Embora a terapia tópica seja frequentemente usada como primeira opção para o tratamento inicial do glaucoma de ângulo aberto (GAA), efeitos colaterais, baixa adesão, entre outros fatores podem comprometer a eficácia do tratamento. Nesse cenário, a trabeculoplastia a laser surge como uma opção terapêutica interessante. Comumente usada como última alternativa antes da cirurgia antiglaucomatosa incisional por muitos anos, a trabeculoplastia a laser tem sido indicada cada vez mais cedo com o advento da trabeculoplastia seletiva a laser (SLT). Nessa revisão, nós avaliamos criticamente as publicações sobre trabeculoplastia a laser como primeira opção para glaucoma de ângulo aberto. Os estudos de SLT como primeira opção terapêutica têm apresentado dados animadores. Os resultados de um ano de acompanhamento mostram eficácia semelhante àquela obtida com análogos de prostaglandinas. Embora o efeito do laser seja transitório, estudos recentes sugerem que o procedimento pode ser repetido com sucesso nos casos que tiveram boa resposta ao primeiro tratamento com SLT.


Subject(s)
Humans , Trabeculectomy/methods , Glaucoma, Open-Angle/surgery , Elective Surgical Procedures , Laser Therapy/methods , Randomized Controlled Trials as Topic , Treatment Outcome
8.
Arq. bras. oftalmol ; 76(6): 363-365, nov.-dez. 2013. tab
Article in English | LILACS | ID: lil-701288

ABSTRACT

PURPOSE: To investigate and describe, among the members of the Brazilian Glaucoma Society (BGS), the practices regarding the perioperative management of anticoagulants (warfarin and aspirin) use in patients scheduled for glaucoma surgery. METHODS: The active members of the Brazilian Glaucoma Society answered a questionnaire evaluating different aspects of their current perioperative management of glaucomatous patients taking warfarin or aspirin. RESULTS: A total of 52 participants returned a complete questionnaire. Warfarin or aspirin was routinely interrupted prior to glaucoma surgery by 82.7% of the respondents. The majority of the surgeons who discontinued these medications reported doing so 7 days prior to surgery and resumed their use the day after the procedure. Almost half of our interviewees reported hemorrhagic complications that could be related to anticoagulant therapy. A large number of the surgeons (86.5%) preferred a particular surgical technique for anticoagulated patients; however, most of them (88.5%) do not change the anesthetic planning in such patients. Finally, the majority of the participants (90.4%) refer their anticoagulated patients to a preoperative appointment with a cardiologist or a general practitioner before the surgery. CONCLUSIONS: The majority of Brazilian Glaucoma Society members participating in this study interrupt either warfarin or aspirin prior to glaucoma surgery. Although there is scant information available in the literature to offer definitive guidance, most participants from the Brazilian Glaucoma Society seem to share the same opinion when it comes to perioperative management of anticoagulant users.


OBJETIVO: Investigar e descrever, entre os membros da Sociedade Brasileira de Glaucoma (SBG), as práticas relativas ao manejo de anticoagulantes (varfarina e aspirina) em pacientes agendados para cirurgia antiglaucomatosa. MÉTODOS: Foi enviado um questionário objetivo aos membros ativos da Sociedade Brasileira de Glaucoma avaliando diferentes aspectos da forma como conduzem seus pacientes em uso de varfarina ou aspirina durante o período perioperatório de uma cirurgia antiglaucomatosa. RESULTADOS: Cinquenta e dois participantes retornaram o questionário preenchido adequadamente. O uso de varfarina ou aspirina foi rotineiramente interrompido antes da cirurgia antiglaucomatosa por 82,7% dos entrevistados. A maior parte dos cirurgiões, quando interromperam o uso destes medicamentos, o fez sete dias antes da cirurgia e os reintroduziram no dia seguinte ao procedimento. Aproximadamente metade dos entrevistados disse ter observado complicações hemorrágicas que poderiam ser relacionados à terapia anticoagulante. Embora a maioria dos cirurgiões (86,5%) referiu utilizar alguma técnica cirúrgica em particular para esses pacientes anticoagulados, quase todos (88,5%) não alteram seu planejamento anestésico de rotina nesses mesmos casos. Finalmente, a maior parte dos participantes (90,4%) relatou referir seus pacientes anticoagulados para uma avaliação pré-operatória com um cardiologista ou um clínico geral. CONCLUSÃO: A maior parte dos membros da Sociedade Brasileira de Glaucoma que participou desse estudo refere interromper o uso de anticoagulantes (varfarina ou aspirina) antes de uma cirurgia antiglaucomatosa. Embora existam poucas informações disponíveis na literatura para oferecer uma orientação definitiva, a maioria dos participantes parece compartilhar da mesma opinião quando se trata do manejo perioperatório de anticoagulantes.


Subject(s)
Female , Humans , Male , Anticoagulants/administration & dosage , Aspirin/administration & dosage , Glaucoma/surgery , Perioperative Period/methods , Practice Patterns, Physicians'/statistics & numerical data , Warfarin/administration & dosage , Anticoagulants , Aspirin , Brazil , Ophthalmology , Risk Factors , Surveys and Questionnaires , Societies, Medical/statistics & numerical data , Time Factors , Warfarin
9.
Arq. bras. oftalmol ; 76(6): 380-382, nov.-dez. 2013. ilus
Article in English | LILACS | ID: lil-701293

ABSTRACT

Pigmented paravenous retinochoroidal atrophy is an ocular disease characterized by outer retina and choroidal atrophy often with overlying intraretinal bone spicule pigment deposition along the retinal veins. As a rare condition, there is scant information in the literature regarding the pattern of inner retinal layers involvement. We present a case of a 41-year-old white man initially referred for a glaucoma evaluation. Fundoscopy revealed patches of retinochoroidal atrophy and light pigmentation extending from the optic nerve head along the inferior-temporal retinal veins in both eyes. Using different spectral-domain optical coherence tomography (SD-OCT) protocols we identified a significant thinning of the inner retinal layers along the inferior-temporal veins, but with a lucid interval surrounding the optic nerve head. Standard automated perimetry revealed a superior absolute arcuate scotoma sparing the central fixation (good structure-functional correlation). This pattern of inner retinal layers involvement was not previously described. We believe SD-OCT added significantly to the anatomical description of this case. Physicians should consider these new anatomical findings and correlate them with functional status while assessing these patients.


Atrofia retinocoroidiana pigmentada paravenosa é uma doença ocular caracterizada por atrofia localizada da coroide e da retina externa associada a áreas de pigmentação em espícula óssea depositada ao longo das veias retinianas. Como é uma condição rara, há pouca informação na literatura sobre o padrão de envolvimento das camadas mais internas da retina. Relatamos o caso de um homem branco, de 41 anos, encaminhado incialmente para avaliação de glaucoma. Apresentava à fundoscopia áreas de atrofia retinocoroidiana com pigmentação leve sobrejacente, estendendo-se desde o disco óptico e seguindo ao longo da veia temporal inferior da retina em ambos os olhos. Por meio de diferentes protocolos da tomografia de coerência óptica de domínio espectral (SD-OCT) identificamos um afinamento significante das camadas internas da retina ao longo da veia temporal inferior, mas com uma área de intervalo lúcido ao redor do disco óptico. A perimetria automatizada acromática revelou um escotoma arqueado superior absoluto, poupando a fixação central em ambos os olhos e correspondendo às áreas de atrofia ao longo das veias retinianas (boa correlação anátomo-funcional). Este padrão de envolvimento das camadas retinianas internas não havia sido descrito anteriormente. Acreditamos que o SD-OCT contribuiu significativamente para a descrição anatômica desse caso e que estes novos achados devam ser considerados e correlacionados com o estado funcional ao avaliar esses pacientes.


Subject(s)
Adult , Humans , Male , Choroid/pathology , Eye Diseases, Hereditary/pathology , Retina/pathology , Retinal Degeneration/pathology , Tomography, Optical Coherence/methods , Optic Disk/pathology , Reproducibility of Results , Retinal Vein/pathology
10.
Arq. bras. oftalmol ; 74(3): 161-162, May-June 2011.
Article in English | LILACS | ID: lil-598306

ABSTRACT

PURPOSE: Low intraocular pressure (IOP) measured by Goldmann applanation tonometry (GAT) is one of the ocular manifestations of Steinert's myotonic dystrophy. The goal of this study was to evaluate the corneal-compensated IOP as well as corneal properties (central corneal thickness and corneal hysteresis) in patients with myotonic dystrophy. METHODS: A total of 12 eyes of 6 patients with Steinert's myotonic dystrophy (dystrophy group) and 12 eyes of 6 age-, race-, and gender-matched healthy volunteers (control group) were included in the study. GAT, Dynamic Contour Tonometry (DCT-Pascal) and Ocular Response Analyzer (ORA) were used to assess the IOP. Central corneal thickness was obtained by ultrasound pachymetry, and corneal hysteresis was analyzed using the ORA device. In light of the multiplicity of tests performed, the significance level was set at 0.01 rather than 0.05. RESULTS: The mean (standard deviation [SD]) GAT, DCT, and corneal-compensated ORA IOP in the dystrophy group were 5.4 (1.4) mmHg, 9.7 (1.5) mmHg, and 10.1 (2.6) mmHg, respectively. The mean (SD) GAT, DCT, and corneal-compensated ORA IOP in the control group was 12.6 (2.9) mmHg, 15.5 (2.7) mmHg, and 15.8 (3.4) mmHg, respectively. There were significant differences in IOP values between dystrophy and control groups obtained by GAT (mean, -7.2 mmHg; 99 percent confidence interval [CI], -10.5 to -3.9 mmHg; P<0.001), DCT (mean, -5.9 mmHg; 99 percent CI, -8.9 to -2.8 mmHg; P<0.001), and corneal-compensated ORA measurements (mean, -5.7 mmHg; 99 percent CI, -10.4 to -1.0 mmHg; P=0.003). The mean (SD) central corneal thickness was similar in the dystrophy (542 [31] µm) and control (537 [11] µm) groups (P=0.65). The mean (SD) corneal hysteresis in the dystrophy and control groups were 11.2 (1.5) mmHg and 9.7 (1.2) mmHg, respectively (P=0.04). CONCLUSIONS: Patients with Steinert's myotonic dystrophy showed lower Goldmann and corneal-compensated IOP in comparison with healthy individuals. Since central corneal thickness and corneal hysteresis did not differ significantly between groups, the lower IOP readings documented in this dystrophy seem not to be related to changes in corneal properties.


OBJETIVOS: Pressão intraocular (PIO) baixa medida por meio da tonometria de aplanação de Goldmann (TAG) é uma das manifestações oculares da distrofia miotônica de Steinert. O objetivo deste estudo foi avaliar a pressão intraocular compensada para as propriedades corneais (espessura corneal central e histerese corneal) em pacientes com distrofia miotônica. MÉTODOS: Um total de 12 olhos de 6 pacientes com distrofia miotônica de Steinert (grupo distrofia) e 12 olhos de 6 voluntários sadios (grupo controle) pareados para idade, raça e sexo foram incluídos no estudo. Tonometria de aplanação de Goldmann, tonometria de contorno dinâmico (TCD-Pascal) e analisador de resposta ocular (ORA) foram usados para medir a pressão intraocular. A espessura corneal central foi obtida por meio da paquimetria ultrassônica e a histerese corneal foi analizada usando o aparelho ORA. RESULTADOS: A pressão intraocular média (desvio-padrão) da TAG, TCD e compensada para a córnea do ORA no grupo distrofia foram 5,4 (1,4) mmHg, 9,7 (1,5) mmHg e 10,1 (2,6) mmHg, respectivamente. A pressão intraocular média (desvio-padrão) da TAG, TCD e compensada para a córnea do ORA no grupo controle foram 12,6 (2,9) mmHg, 15,5 (2,7) mmHg e 15,8 (3,4) mmHg, respectivamente. Houve diferença significativa nos valores da pressão intraocular entre os grupos distrofia e controle obtidas pela TAG (média, -7,2 mmHg; intervalo de confiança (IC) de 99 por cento, -10,5 a -3,9 mmHg; P<0,001), TCD (média, -5,9 mmHg; IC de 99 por cento, -8,9 a -2,8 mmHg; P<0,001) e ORA compensada para córnea (média, -5,7 mmHg; IC de 99 por cento, -10,4 a -1,0 mmHg; P=0,003). A espessura corneal média (desvio-padrão) foi similar nos grupos distrofia (542 [31] µm) e controle (537 [11] µm) (P=0,65). A histerese corneal média (desvio-padrão) nos grupos distrofia e controle foram de 11,2 (1,5) mmHg e 9,7 (1,2) mmHg, respectivamente (P=0,04). CONCLUSÃO: Os pacientes com distrofia miotônica de Steinert apresentaram valores menores de pressão intraocular medidas tanto com Goldmann quanto compensadas para a córnea em comparação com indivíduos sadios. Uma vez que os valores da espessura corneal central e histerese corneal não diferiram significantemente entre os grupos, os valores baixos da pressão intraocular encontrados nos pacientes com distrofia miotônica não parecem estar relacionados com as propriedades corneais.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Cornea/physiopathology , Intraocular Pressure/physiology , Myotonic Dystrophy/physiopathology , Case-Control Studies , Cross-Sectional Studies , Cornea/pathology , Cornea , Corneal Topography/methods , Elasticity/physiology , Tonometry, Ocular/methods
11.
Arq. bras. oftalmol ; 73(4): 354-357, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560610

ABSTRACT

PURPOSE: To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS: Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were excluded. All patients underwent CSLO using the Heidelberg Retina Tomograph III (HRT-III) in one randomly selected eye (three consecutive scans; performed by the same examiner). For each Heidelberg Retina Tomograph III parameter, repeatability was assessed using within subject standard deviation (Sw) and coefficient of variation (CVw), repeatability coefficient (RC) and intraclass correlation coefficient (ICC). Scatter plots and regression lines were constructed to identify which factors influenced test-retest measurement variability. RESULTS: A total of 32 patients were included (mean age, 65.4 ± 13.8 years). Most patients were female (65 percent) and white (50 percent). Among all Heidelberg Retina Tomograph III parameters evaluated, rim area and mean cup depth had the best measurement repeatability. Vertical cup-to-disc ratio (CDR, as determined by optic disc stereophotograph examination) was significantly associated (R²=0.21, p<0.01) with test-retest measurement variability. Eyes with larger CDR showed less variable measurements. Other factors, including age, disc area, central corneal thickness and intraocular pressure were not significant (p>0.14). CONCLUSION: Heidelberg Retina Tomograph III showed good test-retest repeatability for all ONH topographic measurements, mainly for rim area and mean cup depth. Test-retest repeatability seemed to improve with increasing CDR. These findings suggest that HRT-III topographic measurements should be cautiously interpreted when evaluating longitudinally glaucoma patients with early structural damage (small CDR).


OBJETIVO: Determinar os fatores associados à variabilidade (teste-reteste) das medidas topográficas da cabeça do nervo óptico (CNO) utilizando a oftalmoscopia confocal de varredura a laser (CSLO) em pacientes com glaucoma recém-diagnosticados. MÉTODOS: Neste estudo, pacientes com glaucoma primário de ângulo aberto recém-diagnosticados foram prospectivamente incluídos. Aqueles que apresentassem outras doenças oculares (exceto glaucoma) foram excluídos. Todos os pacientes incluídos no estudo foram submetidos à CSLO usando o aparelho Heidelberg Retina Tomograph III (HRT-III) em um olho aleatoriamente selecionado (três exames consecutivos realizados pelo mesmo examinador). Para cada parâmetro do Heidelberg Retina Tomograph III, a repetibilidade foi avaliada através dos seguintes indicadores: desvio padrão (DP) e coeficiente de variação (CV) individual, coeficiente de repetibilidade (CR) e coeficiente de correlação intraclasse (CCI). Diagramas de dispersão e linhas de regressão foram construídos para identificar quais fatores poderiam influenciar a variabilidade das medidas. RESULTADOS: Trinta e dois pacientes foram incluídos no estudo (idade média, 65,4 ± 13,8 anos). A maior parte era composta por mulheres (65 por cento) e pacientes brancos (50 por cento). Dentre os parâmetros de Heidelberg Retina Tomograph III avaliados, a área da rima e a profundidade média da escavação apresentaram os melhores valores de repetibilidade. A relação escavação/disco (E/D) vertical (baseada na análise de estereofotografia do disco óptico), foi significativamente associada (R²=0.21, p<0.01) com a variabilidade teste-reteste. Pacientes com relação E/D maiores apresentaram medidas menos variáveis. Outros fatores como idade, área do disco, espessura corneana central e pressão intraocular não foram significativas (p>0,14). CONCLUSÃO: O Heidelberg Retina Tomograph III mostrou boa repetibilidade (teste-reteste) para todos os parâmetros topográficos da CNO avaliados, principalmente em relação à área da rima e à profundidade média da escavação. A repetibilidade teste-reteste apresentou melhores resultados com o aumento da relação E/D. Esses achados sugerem que as medidas topográficas do Heidelberg Retina Tomograph III devem ser interpretadas com cautela quando avaliarmos longitudinalmente pacientes glaucomatosos com dano estrutural inicial (relação E/D menor).


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Glaucoma, Open-Angle/diagnosis , Ophthalmoscopy/methods , Optic Disk/anatomy & histology , Tomography/methods , Age Factors , Cross-Sectional Studies , Microscopy, Confocal , Ophthalmoscopes/standards , Optic Nerve Diseases/diagnosis , Reproducibility of Results , Sex Factors
12.
Arq. bras. oftalmol ; 72(4): 556-559, July-Aug. 2009. ilus
Article in English | LILACS | ID: lil-528028

ABSTRACT

This case report describes a young non-glaucomatous patient with neurofibromatosis and previous history of optic nerve glioma, which developed multiple wedge-shaped retinal nerve fiber layer defects close to a chorioretinal scar in the fellow eye. After discussing the different possible etiologies to the wedge-shaped defects, the disruption of the nerve fiber layer due to the chorioretinal lesion was considered the most plausible cause. However, further follow-up with visual field assessment, optic nerve head documentation and neuroimaging is mandatory in this case and may provide additional information to better understand it.


Este relato de caso descreve um paciente jovem, sem diagnóstico de glaucoma, portador de neurofibromatose e com história prévia de glioma de nervo óptico em um olho, que desenvolveu múltiplos defeitos localizados na camada de fibras nervosas próximos a uma cicatriz coriorretiniana no olho contralateral. Depois de discutir as diferentes etiologias possíveis para os defeitos localizados, a desorganização da camada de fibras nervosas secundária à lesão coriorretiniana foi considerada a causa mais plausível. Contudo, futuro acompanhamento com campo visual, documentação da cabeça do nervo óptico e neuroimagem é mandatório neste caso e pode fornecer informações adicionais para melhor entendê-lo.


Subject(s)
Humans , Male , Young Adult , Choroid Diseases/pathology , Cicatrix/pathology , Neurofibromatosis 1/pathology , Optic Nerve Glioma/pathology , Retinal Diseases/pathology , Magnetic Resonance Imaging , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL